ATS1202

8 input expander for ATS120x(E)
  • Expandable to maximum 32 zones
  • Depending on DGP or Panel, 2 or 3 expander modules can be fitted
  • Compatible with Axon and Advisor Advanced panels
  • Unit can be daisy chained easily
View all

At a glance

Product overview

Input expanders are devices for expanding the input capacity of an advisor MASTER panel or a DGP. Depending on the basic capacity of the panel up to 3 x ATS1202 input expanders can be used. The unit easily can be daisy chained.

Expanding features

A standard 8 zone DGP can have eight zones connected to it. This can be expanded in increments of 8, up to 32, using the ATS1202 8-Zone expanders (A DGP can have 8, 16, 24 or 32 zones). A control panel can have 8 or 16 zones connected to it (depending on control panel type). There are sixteen zones allocated to every DGP address. This can be incremented to a maximum of 32 zones by fitting ATS1202 expander modules. If a DGP has 24 or 32 zones (two or three expanders fitted), the
additional system zone numbers are taken from the following DGP address. If this is done, the next DGP address ceases to exist and is not included to be polled e.g. DGP 1 has 24 zones (zones 17 to 40). The next DGP in the system must now be addressed and polled as DGP 3, because zones 33 to 40 on DGP 1 have been taken from DGP 2.

Details

  • Expandable to maximum 32 zones
  • Depending on DGP or Panel, 2 or 3 expander modules can be fitted
  • Compatible with Axon and Advisor Advanced panels
  • Unit can be daisy chained easily

Technical specifications

General
Expander type
Input expander
Product line
Advisor Advanced
ATS Master
Axon
Connection type
Plug-in
Compatibility
Axon, Advisor Master, AST120xE and ATS121xE expanders
Max. distance from panel
Located in Panel or DGP/Expander housing
Max. per panel
Up to 3 depending on Panel or DGP/Expander
System
Addressing
DIP Switches
Inputs
Total
8
Onboard
8
Outputs
Siren outputs
no
Electrical
Power supply type
12 VDC
Power supply value
10.5-13.8 VDC provided by panel/expander
Current consumption
10 mA
Integrated power supply
No
Physical
Physical dimensions
80 x 52 mm
Environmental
Operating temperature
-10 to +55°C
Relative humidity
95% noncondensing
Environment
EN50130-5 ; Class II - Indoor (general)
Regulatory
Compliancy
CE
Certification
CE

Downloads

All downloads

Datasheet

Installation sheet

Other EU certificate

Certificates