ATS1236
32 zones 433 MHz wireless receiver DGP
- Expands the Axon panel or Advisor Advanced panel with 32 wireless zones
- Includes two wired zone inputs
- One programmable SPDT Form C relay output
- Supports legacy 63-bit 433 MHz and new LoNa 433 MHz transmitters (one way)
- Use the Aritech 433 LoNa repeater to improve range
Related products
At a glance
Product overview
The ATS1236 wireless receiver adds wireless capabilities to the Advisor Advanced range of panels.
The wireless expander supports most of the legacy 433 MHz 63-bit transmitters as well as the new generation of 433 MHz LoNa transmitters of which the wireless communication is fully encrypted, avoiding unauthorized interference. Up to 32 wireless sensors and up to 16 keyfobs can be learned in.
The ATS1236 wireless receiver provides two wired zone inputs and one programmable relay output.
Installation and programming
The wireless DGP needs to be installed outside the panel housing in order to assure a maximum wireless range. The 433 MHz wireless solution will monitor the status and presence of each wireless device and will respond in case of an RF jamming condition.
The ATS1236 wireless receiver can be programmed from the keypad as well as from the downloader. The firmware of the module is remotely upgradeable.
Expanders
Expanders are used to expand the number of alarm inputs in an Advisor Advanced system. Expanders allow inputs and outputs/relays to be connected at a location remote from an Advisor Advanced panel. Expanders communicate via poll & reply messages. Detectors, door contacts and other detection devices are connected to expanders that report any change of state to the control panel for processing. Available expanders include support for conventional devices, wireless devices as well as intelligent addressable devices. A special expander is available providing expansion of four to eight intelligent doors or lifts.
Up to 15 or 30 expanders can be connected to an Advisor Advanced depending on the variant.
System databus connection
The system databus is used to connect expanders as well as keypads and readers (RASs) to the Advisor Advanced control panel. Remote devices can be up to 1.5 km from a control panels when using the preferred wiring and cable types. Keypads, readers and expanders have to be connected via a 2 pair twisted and shielded data cable to the system databus connection to achieve this. (WCAT52 is recommended). Daisy chain is the preferred wiring method. The shield of the data cable should be connected to earth at the control panel and should be left disconnected at any other end.
If a failure in communication occurs, the expander remembers the last alarm in a system preventing loss of an alarm due to a short interruption in data communication.
Details
- Expands the Axon panel or Advisor Advanced panel with 32 wireless zones
- Includes two wired zone inputs
- One programmable SPDT Form C relay output
- Supports legacy 63-bit 433 MHz and new LoNa 433 MHz transmitters (one way)
- Use the Aritech 433 LoNa repeater to improve range
- Quick configuration using the Aritech "Learn Mode" technology
- Removable terminals
- EN50131-1/EN50131-3/EN50131-6 Grade 2 Class II, INCERT
- Firmware upgradeable
- Located up to 1500 m from the Axon panel or the Advisor Master panel using WCAT52/54 cable
Technical specifications
| General | ||
|---|---|---|
| Expander type |
Wireless expander
|
|
| Product line |
Advisor Advanced
Axon
|
|
| Connection type |
Databus connection
|
|
| Compatibility |
433 MHz 63 bit and 433 MHz LoNa (one way sensors), Advisor Advanced MR 4.2 or higher, Axon MR1.0 or higher
|
|
| Max. distance from panel |
1.5 km
|
|
| Max. per panel |
15 on one panel bus
|
|
| Specified cable |
WCAT52 / WCAT54 or equivalent
|
|
| System | ||
|---|---|---|
| Addressing |
DIP Switches
|
|
| Inputs | ||
|---|---|---|
| Total |
32
|
|
| No. of wireless zones |
32 wireless sensors (one way)
|
|
| Onboard |
2 wired inputs
|
|
| Outputs | ||
|---|---|---|
| Total |
1
|
|
| Onboard |
1
|
|
| Type of outputs |
SPDT Form C relay
|
|
| Wireless | ||
|---|---|---|
| Operating frequency |
433 MHz legacy
433 MHz LoNa
|
|
| Electrical | ||
|---|---|---|
| Operating voltage |
9.5 to 14.4 VDC
|
|
| Current consumption |
typical 45 mA @ 12 VDC
max. 56 mA @ 9.5 VDC
|
|
| Integrated power supply |
No
|
|
| Physical | ||
|---|---|---|
| Physical dimensions |
165 x 115 x 40 mm
|
|
| Net weight |
160 g
|
|
| Colour |
White
|
|
| Material |
ABS plastic
|
|
| Environmental | ||
|---|---|---|
| Operating temperature |
-10 to +55°C
|
|
| Relative humidity |
95% noncondensing
|
|
| Environment |
EN50130-5 ; Class II - Indoor (general)
|
|
| Regulatory | ||
|---|---|---|
| Compliancy |
CE
|
|
| Certification |
CE
EN50131 Grade 2
INCERT
|
|
Downloads
All downloadsDatasheet
Installation sheet
Technical documentation
Other EU certificate
Other EU certificate
C-001-1601/A
Other EU certificate
1221100036A16
Other EU certificate
1231100032B15
Other EU certificate
1223000003A17
Other EU certificate
1231100043A15
Other EU certificate
1233000005A17
Other EU certificate
1221100045C0
Other EU certificate
1231100045A0
Other EU certificate
1231100045C0
Other EU certificate
1231100045B0
Other EU certificate
1221100045C1
Other EU certificate
1231100045A1
Other EU certificate
1231100045B1
Other EU certificate
1231100045C1
Other EU certificate
1231100045D0
Other EU certificate
1223000009A1
Other EU certificate
1233000006A1
Other EU certificate
1233000007A1
Other EU certificate
C-001-1601/B
Other EU certificate
1233000008A1
Certificates
If available, the downloads of the Certificates, Software & Firmware and Media are displayed in their default language.