1-23911-K070
FireBeta XT Ancillary PCB
- Potential free contacts for remote signaling of extinguishing system status
- Supervised, 2-wire RS485 data connection
- Up to 7 boards per system
- LED indicators confirm relay operation
- May be mounted inside the extinguishing panel cabinet or remotely
At a glance
General
The FireBeta XT ancillary boards are accessories to the EN approved FireBeta XT/XT+ extinguishing control panels. These ancillary boards extend the signals from the extinguishing system to other control or signalling equipment e.g. the building management (BMS) or other fire alarm systems that may be present in the building.
Up to 7 ancillary boards can be connected to the FireBeta XT/XT+ control panel via a fully monitored RS485 communication link. This allows for the same signalling capabilities at multiple locations up to 1200 m away from the main control panel.
Every ancillary board is provided with 10 potential free changeover contact outputs, each allocated to a specific extinguishing system function. On board status LEDs are provided to indicate the status of each output These LEDs illuminate when the output is active.
Ancillary boards may be mounted inside the extinguishing control panel cabinet or remotely in external enclosures. Every ancillary board is given a unique address to enable accurate location reporting of communication faults between the panel and the board.
Ancillary boards may be mounted inside the extinguishing control panel cabinet or remotely in external enclosures. Every ancillary board is given a unique address to enable accurate location reporting of communication faults between the panel and the board.
Supported Output Functions
The following area status can be signaled:
▍ Zone 1 fire
▍ Zone 2 fire
▍ Zone 3 fire
▍ Manual only mode activated
▍ Disablement active
▍ Gas release confirmation
▍ Extinguishing release countdown activated
▍ Manual release operated
▍ Extract fan output operated
▍ Hold circuit activated
▍ Zone 1 fire
▍ Zone 2 fire
▍ Zone 3 fire
▍ Manual only mode activated
▍ Disablement active
▍ Gas release confirmation
▍ Extinguishing release countdown activated
▍ Manual release operated
▍ Extract fan output operated
▍ Hold circuit activated
Details
- Potential free contacts for remote signaling of extinguishing system status
- Supervised, 2-wire RS485 data connection
- Up to 7 boards per system
- LED indicators confirm relay operation
- May be mounted inside the extinguishing panel cabinet or remotely
Technical specifications
| General | ||
|---|---|---|
| Status indicaton |
LEDs
|
|
| Compatibility |
FireBeta XT/XT+
|
|
| Connectivity |
Two wire RS485
|
|
| Communication ports |
1
|
|
| Electrical | ||
|---|---|---|
| Power supply type |
VDC
|
|
| Operating voltage |
20 to 30 VDC
|
|
| Current consumption |
0.175 A
|
|
| Output | ||
|---|---|---|
| Output quantity |
10
|
|
| Output type and rating |
Potential free relays, 1 A @ 30 VDC
|
|
| Physical | ||
|---|---|---|
| Form factor |
PCB
|
|
| Physical dimensions |
155 x 136 mm
|
|
| Colour |
Green
|
|
| Mounting type |
PCB mount
|
|
| Environmental | ||
|---|---|---|
| Vandal proof |
No
|
|
| Operating temperature |
-5°C to +50°C
|
|
| Relative humidity |
< 95% (non condensing)
|
|
| Environment |
Indoor
|
|
| Regulatory | ||
|---|---|---|
| Compliancy |
REACH
RoHS 2
WEEE
|
|
| Certification |
CE
|
|
Downloads
All downloadsDatasheet
Certificates
If available, the downloads of the Certificates, Software & Firmware and Media are displayed in their default language.