Skip to main content

1-23911-K070

FireBeta XT Ancillary PCB
  • Potential free contacts for remote signaling of extinguishing system status
  • Supervised, 2-wire RS485 data connection
  • Up to 7 boards per system
  • LED indicators confirm relay operation
  • May be mounted inside the extinguishing panel cabinet or remotely
View all

At a glance

General

The FireBeta XT ancillary boards are accessories to the EN approved FireBeta XT/XT+ extinguishing control panels. These ancillary boards extend the signals from the extinguishing system to other control or signalling equipment e.g. the building management (BMS) or other fire alarm systems that may be present in the building.
Up to 7 ancillary boards can be connected to the FireBeta XT/XT+ control panel via a fully monitored RS485 communication link. This allows for the same signalling capabilities at multiple locations up to 1200 m away from the main control panel.
Every ancillary board is provided with 10 potential free changeover contact outputs, each allocated to a specific extinguishing system function. On board status LEDs are provided to indicate the status of each output These LEDs illuminate when the output is active.

Ancillary boards may be mounted inside the extinguishing control panel cabinet or remotely in external enclosures. Every ancillary board is given a unique address to enable accurate location reporting of communication faults between the panel and the board.

Supported Output Functions

The following area status can be signaled:
▍ Zone 1 fire
▍ Zone 2 fire
▍ Zone 3 fire
▍ Manual only mode activated
▍ Disablement active
▍ Gas release confirmation
▍ Extinguishing release countdown activated
▍ Manual release operated
▍ Extract fan output operated
▍ Hold circuit activated

Details

  • Potential free contacts for remote signaling of extinguishing system status
  • Supervised, 2-wire RS485 data connection
  • Up to 7 boards per system
  • LED indicators confirm relay operation
  • May be mounted inside the extinguishing panel cabinet or remotely

Technical specifications

General
Status indicaton
LEDs
Compatibility
FireBeta XT/XT+
Connectivity
Two wire RS485
Communication ports
1
Electrical
Power supply type
VDC
Operating voltage
20 to 30 VDC
Current consumption
0.175 A
Output
Output quantity
10
Output type and rating
Potential free relays, 1 A @ 30 VDC
Physical
Form factor
PCB
Physical dimensions
155 x 136 mm
Colour
Green
Mounting type
PCB mount
Environmental
Vandal proof
No
Operating temperature
-5°C to +50°C
Relative humidity
< 95% (non condensing)
Environment
Indoor
Regulatory
Compliancy
REACH
RoHS 2
WEEE
Certification
CE

Downloads

All downloads

Datasheet

Certificates

If available, the downloads of the Certificates, Software & Firmware and Media are displayed in their default language.